SHAANXI AIRMEXT TECHNOLOGY INDUSTRIAL CO.,LTD.

WE WILL NEVER LET YOU DOWN

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Air Suspension Accessories /

SN420 Super Silent Air Pump Air Compressor 200PSI DC 12V

Contact Now
SHAANXI AIRMEXT TECHNOLOGY INDUSTRIAL CO.,LTD.
Visit Website
Province/State:Shaanxi
Country/Region:china
Contact Person:Mrscora
Contact Now

SN420 Super Silent Air Pump Air Compressor 200PSI DC 12V

Ask Latest Price
Video Channel
Brand Name :AIRMEXT
Model Number :SN360
Certification :CE
Place of Origin :CN
MOQ :1
Price :USD 100~150
Payment Terms :T/T
Supply Ability :500 PCS/MONTH
Delivery Time :1~3 WORKING DAYS
Packaging Details :CARTON BOX&BUBBLE PACKING
RRated voltage :DC-12V
Max Amperage :20 Amps
Motor type :Permanent Magnetic Motor
Max. Working Pressure :200PSI
Duty Cycle :100% @100PSI &73.4℉
Overheating protection :Yes
Dimensions :12″L x 4.4″W x 7.52″H
Net Weight :9.7 lbs.
Flowrate at 0 PSI :40L/min ,1.41CFM
Flow rate at 150PSI :21L/min ,0.74CFM
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
SN420 Super silent air pump air compressor
Pls note this product is sold by piece!
Brand: AIRMEXT
More detailed product installation parameters, performance parameters, electrical parameters, environmental parameters, please contact customer service to obtain information
Model: SN420 (SUPER SILENT)
Operating Voltage: DC-12V
Motor type: Permanent magnet motors
Working voltage: 200PSI
Inflatable Flow: 1.41CFM@0PSI(1CFM=28.3185 L/MIN)
Inflatable Flow: 0.74CFM@150PSI(1CFM=28.3185 L/MIN)
Maximum working pressure: 200PSI (14KG / cm2)
Maximum current: 38A
Size (L × W × H, mm): 277x106x168
Weight: 5KG
SN 420 is a 100% duty cycle of the air compressor
High performance, durable piston rings, precision motor bearings, work quickly and efficiently
Traffic at 0PSI pressure of (1.41CFMCFM)
Original standard; 3/8 "stainless steel package bobbin, mounting hardware (nuts, bolts, lock washers), isolator, air filter assembly, nylon pressure pipe, a valve interfaces with check valve and so on
AIRMEXT is Standard setters, famous and world renowned. Products involved in numerous aerospace, automotive, ships, high-speed railway, machinery.
In the automotive industry, widely used in air suspension systems, air horn, pneumatic doors, pneumatic seat, clutch, power steering systems

TROUBLESHOOTING GUIDE:

PROBLEM: POSSIBLE CAUSE(S) CORRECTiVE ACTION

Tank pressure drops when

compressor(s) shut off

1. Loose drain cock

2.Check valve leaking

3. Loose connections

1. Tighten drain cock

2. Replace check valve or

compressor

3. Check all connections with

soap and water solution

and tighten

Compressor runs

continuously and air flow

lower than normal

1.Excessive air usage

2. Loose connections

3. Worn piston ring or inlet valve.

4.Clogged air filter element

1. Decrease air usage

2. Check all connections with

soap and water solution

and tighten

3. Replace compressor

4. Replace air filter element

Compressor runs

continuously causing

safety valve(if equipped)

to open

1.Faulty pressure switch

2.Defective safety valve

1. Replace pressure switch

2. Replace safety valve

Excessive moisture in

discharge

1.Excessive water in air tank

2.High humidity

1. Drain tank, tilt tank to drain.

Drain tank more frequently

2. Move compressor to area

with less humidity, or use

air line filter

Compressor will not run

1. No power, or power switch in

OFF position

2. Blown fuse

3. Motor overheats

4. Faulty pressure switch (if

hooked up to a pressure switch)

1. Make sure compressor

switch is ON

2. Disconnect compressor

from power source, replace

fuse. ( Refer to Specifications

section for correct fuse amperage)

3. Let compressor cool off for

about 30 minutes to allow t

hermal overload switch to reset

4. Replace pressure switch

Thermal overload

protector cuts out

repeatedly

1. Lack of proper ventilation or

ambient temperature is too high

2. Compressor valves failed

1. Move compressor to well

ventilated area, or area with

lower ambient temperature

2. Replace compressor

Excessive knocking

or rattling

1. Loose mounting bolts

2.Worn bearing on eccentric or

motor shaft

3.Cylinder or piston ring is worn

1. Tighten bolts

2. Replace bearing or

piston assembly

3. Replace piston or compressor


WIRE GUAGE GUIDE 12-VOLT
SN420 Super Silent Air Pump Air Compressor 200PSI DC 12V
SN420 Super Silent Air Pump Air Compressor 200PSI DC 12VSN420 Super Silent Air Pump Air Compressor 200PSI DC 12VSN420 Super Silent Air Pump Air Compressor 200PSI DC 12VSN420 Super Silent Air Pump Air Compressor 200PSI DC 12VSN420 Super Silent Air Pump Air Compressor 200PSI DC 12VSN420 Super Silent Air Pump Air Compressor 200PSI DC 12V